Alytech Launches ZEPHYR II Smart Gas Diluter | GasMix™

NEW PRODUCT  ·  MAY 2026

Alytech Launches ZEPHYR II: The Next Generation Smart Gas Diluter from GasMix™

Juvisy-sur-Orge, France, May 2026. Alytech is proud to announce the launch of ZEPHYR II, the next generation of the GasMix™ smart gas diluter with two channels. ZEPHYR II is the first ZEPHYR to run AlySoft, the unified software platform behind every GasMix™ product, on an internal PC inside the instrument. The new gas diluter delivers unlimited stored sequences, live mixture generation on demand, real time uncertainty calculation, and a fully exportable audit trail. It is ISO 6145-7 compliant, delivers ±1% of setpoint flow accuracy*, and produces accurate gas mixtures from percent down to parts per billion (ppb).

ZEPHYR II is available now and can be configured for analytical laboratories, refineries, research centres, and process industries that need traceable, repeatable gas mixtures from a single calibration standard.

Discover the full ZEPHYR II product page →

Why the ZEPHYR II smart gas diluter matters

AlySoft has powered the GasMix™ range for years. It is the software platform behind the AIOLOS III multichannel gas mixer, Nomad, Hurricane, and the rest of the family. ZEPHYR II is the launch that brings AlySoft to the most compact gas diluter in the catalogue.

That single change has consequences across the whole instrument. The original ZEPHYR was firmware bound: ZeSoft, a closed dedicated firmware, with all the limits firmware brings. Ten stored sequences. A limited gas library. No live setpoint changes during a run. No exportable audit trail. No continuous quality follow-up. ZEPHYR II is software native from the ground up. Every limit removed by AlySoft, every capability AlySoft has gained over the years, every workflow it has standardised across the GasMix™ range now lives inside the ZEPHYR II gas diluter as well.

For a laboratory already running an AIOLOS III or another GasMix™ instrument, ZEPHYR II joins the same ecosystem. One software platform. One learning curve. One set of methods, transferable from instrument to instrument. For laboratories evaluating dynamic gas dilution against calibration cylinders for the first time, ZEPHYR II offers the entry point to the GasMix™ range without compromise on software or traceability.

What is new in ZEPHYR II compared to the original ZEPHYR

Here is exactly what ZEPHYR II changes, point by point, versus the original ZEPHYR smart gas diluter.

Original ZEPHYR

ZEPHYR II

Software platform

ZeSoft (dedicated firmware)

AlySoft, the unified GasMix™ platform

Computing architecture

Embedded firmware

Built-in PC

Stored sequences

10 max

Unlimited

Gases and methods

Limited library

Unlimited

Touchscreen

5″ resistive

7″ capacitive (faster, more responsive)

Live mixture changes

Not possible during a run

Immediate mode (live setpoint changes)

Uncertainty calculation

Automatic

Automatic, live, in real time

Continuous quality follow-up

Not available

Yes

Audit trail

Not available

Exportable, ready for ISO/IEC 17025 and GLP

USB data export

Not available

One-click export

Software upgrades

Firmware reflash

Seamless AlySoft updates

Cross-instrument workflow

ZEPHYR specific

Shared with the rest of the GasMix™ range

The dilution physics is unchanged. The same ±1% accuracy, less than 0.1% repeatability*, 1:2000 dilution ratio (extendable to 1:10,000), and ISO 6145-7 compliance that ZEPHYR has been trusted for since the original launch. What changes is everything around the dilution: the software, the documentation, the workflow.

Four breakthroughs that define the ZEPHYR II gas diluter

Each of the changes above sounds incremental on its own. Together, they redefine what a compact gas diluter can do.

1. ZEPHYR joins the AlySoft ecosystem

This is the single biggest change. AlySoft is the software platform Alytech designed to make every GasMix™ instrument behave like part of one larger system: shared methods, shared sequences, shared audit trails, shared learning curve. ZEPHYR was the only GasMix™ gas diluter that sat outside this ecosystem. With ZEPHYR II, that is no longer the case. Operators who already work with an AIOLOS III, a Hurricane, or any other GasMix™ instrument open ZEPHYR II for the first time and find a familiar interface.

“ZEPHYR II is the moment our compact gas diluter joins the same software platform as the rest of the GasMix™ range. The dilution accuracy has not changed, that has been proven for years. What changes is how the user interacts with the instrument, stores their methods, and documents their results. ZEPHYR II brings calibration into the same workflow as the rest of a modern laboratory.”

2. Live mixture generation, on demand

ZEPHYR II introduces Immediate mode alongside the classic Sequences mode. Operators can adjust flow rates or target concentrations live, during a run, without stopping or restarting the sequence. On a firmware bound diluter, the only way to change a setpoint mid experiment was to stop, edit, and start again. ZEPHYR II removes that constraint entirely. This is exactly the mode you need for spike recovery experiments, exploratory linearity work, or any setup where the next setpoint depends on what the analyser just reported.

3. Unlimited sequences, gases, and methods

The original ZEPHYR stored up to ten sequences. ZEPHYR II removes that ceiling completely. Store as many sequences, gas definitions, and methods as your laboratory needs. Configure complex multipoint calibration programmes directly on the instrument, recall them with a tap, and run them unattended in synchronisation with your analyser. For accredited laboratories maintaining method libraries across several analysers and several analytes, this single change saves hours of operator time every week.

4. Live uncertainty and exportable audit trail

ZEPHYR II is built for regulated and quality driven environments: ISO/IEC 17025, GLP, pharmaceutical QC, refinery process laboratories. Uncertainty is calculated live, in real time, propagating the cylinder’s certified uncertainty and the actual flow conditions into the final result. The full run is captured in an exportable audit trail. Data exports to USB with one click. And because ZEPHYR II runs AlySoft, future updates are delivered as seamless software upgrades over the lifetime of the instrument, not firmware reflashes.

Where the ZEPHYR II gas diluter fits in the laboratory

ZEPHYR II is designed for any workflow where a stable, traceable, multipoint gas mixture is the rate limiting step. Typical applications include:

       Linearity verification and calibration of gas chromatographs equipped with FID, TCD, PID, PHD, SCD, MS, and other detectors

       Calibration of gas analysers for refinery and petrochemical process control applications

       Linearity verification and calibration of trace elemental analysers

       Validation and calibration of microGC systems for biogas characterisation

       Generation of controlled atmospheres in reactors for ageing, oxidation, or stability studies in research and development environments

       Trace level gas generation for hydrogen fuel quality verification, environmental monitoring, and specialty gas mixtures

In each case, the ZEPHYR II smart gas diluter replaces a bank of fixed concentration cylinders with a single parent standard and a diluent, reducing operator handling, cylinder logistics, and the safety footprint of the calibration bench.

ZEPHYR II technical specifications

Gas channels

2

Flow accuracy

±1% of setpoint *

Repeatability

less than 0.1% of setpoint *

Dilution ratio

1:2000 standard, up to 1:10,000

Concentration range

% to ppb, fully programmable

Response time

less than 5 s

Outlet pressure

Up to 7 bar(g)

Standard

ISO 6145-7 compliant

Wetted materials

316L stainless steel tubing, Kalrez® seals

Gas compatibility

Aggressive gases and active compounds (trace sulfurs, NOx, NH₃, VOCs)

Analyser synchronisation

TTL or dry contact

Touchscreen

7″ capacitive

Software

AlySoft on internal PC

Power

90 to 260 VAC, 50 to 60 Hz

Weight

6.5 kg

Dimensions (L × W × H)

43 × 15 × 25 cm

Battery (option)

Rechargeable internal battery, up to 6 hours autonomy

* When MFCs operate between 10% and 100% of full scale flow.


Availability and contact

ZEPHYR II is available to order now from GasMix™ and our authorised partners worldwide. Configurations, lead times, and demo sessions with our technical team are available on request.

To explore the full technical detail, configuration options, and applications of the ZEPHYR II smart gas diluter, visit the product page.

Discover the full ZEPHYR II product page →

To discuss your specific application and request a configuration recommendation, get in touch with our team.

Contact us: gasmix@alytech.fr  ·  +33 1 69 56 07 17

Talk to our technical team →

Scroll to Top

This site use cookies to provide you the best user experience. By continuing to use the site, you accept our use of cookies. More information

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close