Zephyr II

GASMIX™ COMPACT

ZEPHYR II — Compact 2-Channel Gas Mixer & Gas Diluter

Zephyr II is a compact, all-in-one 2-channel gas mixer and gas diluter for on-site calibration. It combines one span gas and one diluent to generate precise standards on demand, with embedded AlySoft™, ISO 6145-7 compliance and optional battery for 6 hours of autonomous operation.

GasMix Zephyr II compact 2-channel gas mixer and gas diluter

ZEPHYR II — 2-Channel Gas Mixer for On-Site Calibration

A 2-channel gas mixer combines one span gas and one diluent to generate precise calibration standards on demand — the simplest and most portable configuration for routine multi-point calibration. 

ZEPHYR II  brings on-site customized gas standard preparation to a compact footprint. Thanks to its embedded AlySoft and 7″ touch interface, Zephyr can be installed exactly where you need it: on a bench, in a mobile lab or next to the analyzer. It is widely used for applications that involve only two gases, such as multi-point calibration from a concentrated standard plus diluent.

The interface is intuitive and fully automated: run a single injection or a pre-programmed sequence. AlySoft computes the target flows, calculates uncertainty of the final concentration (considering MFC flows and parent gas certificate) and logs events for traceability.

Smart Sequence Builder creates multi-point curves in one click — choose number of points, start/stop concentrations, and the software generates the levels automatically. Optional battery guarantees up to 6 hours of uninterrupted operation in the field or during mains cut-off.

Technical Specifications

Everything the ZEPHYR II delivers, at a glance.

🎯 Dilution Performance
Gas channels 2
Dilution ratio 1:2 000 standard — up to 1:10 000 max
Flow accuracy ±1 % of setpoint *
Repeatability < 0.1 % of setpoint *
Response time < 5 s
Accuracy & Traceability
Standard ISO 6145-7 compliant
Traceability 400-point factory MFC calibration, NIST-traceable
Pressure & Connections
Inlet pressure 3 bar(g) nominal (max. 8 bar(g))
Outlet pressure up to 7 bar(g)
Wetted materials Stainless steel 316 with inert coating, Kalrez® seals
Connections Swagelok® 1/8″ (others on request)
Interface & Power
Interface 7″ color touchscreen, embedded AlySoft™
Power supply 90–260 VAC, 50–60 Hz
Optional battery Internal rechargeable NiCad — up to 6 h autonomy
Operating temperature 10–50 °C
Physical
Dimensions (L × W × H) 43 × 15 × 25 cm
Weight 6.5 kg

* When MFCs operate between 10 % and 100 % of full-scale flow.

Accuracy & Traceability — ISO 6145-7 Compliant Gas Diluter

Every integrated Mass Flow Controller (MFC) undergoes 400-point factory calibration across the full dynamic range and for each selected gas matrix (He, Ar, CH4, H2, N2, Air, CO2…). This ensures superior linearity and precision, especially at very low and very high flow rates.

ISO 6145-7 compliant

NIST-traceable calibration

Uncertainty calculation

±1% set point accuracy and <0.1% repeatability *

Dilution factor: 2 000 in standard — up to 10 000

Analyzer sync via dry contact/TTL

* When MFCs operate between 10% and 100% of full-scale flow.

Key Benefits

Compact & Simple

Small footprint, embedded control, no external PC required.

6 h Autonomy

Optional battery for uninterrupted field operation.

Accurate by Design

Multi-point MFC curves, uncertainty computation, traceability.

Smart Sequences

One-click multi-point curve builder and automated runs.

Aggressive Gases

SS316 + inert coating, Kalrez® seals; Compatible with sulfurs, NOx, NH₃, HF, VOC...

Analyzer-Friendly

Dry contact/TTL sync; stable flows for GC, µGC and analyzers.

Software & Automation for the ZEPHYR II Gas Mixer

ZEPHYR is operated via the built-in AlySoft on a 7″ touch screen — no PC required. It can also exchange signals with an analyzer via dry contact or TTL. Projects store gas libraries, MFC calibration curves per gas, user settings and analyzer sync parameters.

Touch-first UI with embedded control — plug & mix

Smart Sequence builder for multi-point recipes

Real-time adjustment of flow rates and concentrations

Automatic uncertainty calculation and reporting

Compatible with aggressive/reactive gases

Battery option for 6 h autonomous operation

Applications

Linearity check and calibration of GC (FID/TCD/PID/PHID/SCD/MS); refinery process analyzers; trace elemental analyzers; microGC for biogas; synthetic atmospheres in reactors/glove boxes; steam dilution and general two-gas mixing.

Environmental Monitoring

Calibration of ambient air analyzers; multi-point validation of NO, SO₂, CO, CO₂, O₃.

Chemical, Oil & Gas

Calibration of GC, µGC, RGA/NGA, elemental, LPG analyzers and spectrometers.

Research & Academia

Custom mixtures for method development; linearity, LOD/LOQ and hysteresis testing.

Specialty Gases & Food

Secondary standards and VOC/aroma analysis; inert version for aggressive gases.

Is the Zephyr II the right model for you?

Compare the ZEPHYR II with adjacent GasMix systems to find your best fit.

You're viewing ZEPHYR II AIOLOS III NOMAD
Best for Simplest, most compact setup Modular, multi-gas — highly configurable On-site / field use
Gas channels 2 2 to 6 Portable dilution
Configuration Fixed, plug-and-play Many options available — tailored to your setup Compact, battery-ready
Ideal use 1 standard + 1 diluent Evolving, complex gas mixtures Portable calibration anywhere

FAQ — ZEPHYR II

Most asked questions about compact two-gas mixing, automation and metrology.

Standard 1 : 2 000
Extended up to 1 : 10 000

No. PC is inside. 
It includes embedded AlySoft with a 7″ touch UI. It can communicate with an analyzer via dry contact/TTL.

Yes.
Standard build uses SS316 with inert passivation and Kalrez® seals; suitable for sulfurs, NOx, NH₃, VOC and more. Contact us for specifics.

Inlet : 3 bar(g) nominal and max 8 bar(g)
Outlet : atmospheric up to 7 bar(g)
Dimensions : 43 × 15 × 25 cm
Weight : 6.5 kg

Yes.
Optional battery provides up to 6 hours of autonomous operation.

Flow accuracy is ±1 % of setpoint with repeatability below 0.1 % (MFCs operating at 10–100 % of full scale). The uncertainty of every mixture is calculated automatically per ISO 6145-7 and printed on the certificate.

Yes. From a single reference standard and a diluent, it generates an unlimited range of concentrations on demand reducing the number of cylinders you buy, store and handle.

Ready to Mix On Site with ZEPHYR II ?

Create on-demand standards with a compact, touch-first GasMix™ diluter.

Scroll to Top