Dynamic Mixing
Flexible generation of standards from 2 to 6 gas channels.
GASMIX™ PLATFORM
AIOLOS III is AlyTech’s third-generation of GasMix™ dynamic gas mixer and diluter, designed by engineers & chemists, to generate calibration gas standards directly on site — from percent down to trace levels. By mixing and/or diluting two to six gases, AIOLOS III delivers precise, reproducible concentrations with full traceability and certified metrological accuracy.
Developed and manufactured in France, the instrument builds on 20+ years of GasMix™ experience in laboratory and industrial gas preparation. Its modular, customizable design lets you tailor configurations for multi-point calibration, linearity checks, LOD/LOQ validation, research studies and more...
Compact and robust, and compliant with ISO 6145-7, AIOLOS III ensures dependable performance for laboratories that demand accuracy, flexibility and long-term reliability.
AIOLOS III is operated via dedicated GasMix™ software, providing unified control of channels, flow parameters and sequences through an intuitive interface. The platform performs all calculations — mixture ratios, dilution curves and documentation — and synchronizes with external analyzers for fully automated routines.
Every integrated Mass Flow Controller (MFC) undergoes 400-point factory calibration across the full dynamic range and for each selected gas matrix (He, Ar, CH4, H2, N2, Air, …). This ensures superior linearity and precision, especially at very low and very high flow rates.
Flexible generation of standards from 2 to 6 gas channels.
400-point MFC calibration curves applied per gas matrix.
Sequences plus analyzer sync minimize operator bench time.
Generate certificates, uncertainty reports and Audit Trail logging.
Proven compliance for calibration and validation routines.
Options: injection valve, FReD flow regulator, heated lines, multiplexer...
AIOLOS III supports environmental monitoring, chemical/O&G, research labs and specialty gases — enabling multi-point calibration, linearity checks, LOD/LOQ validation and more.
Calibration of ambient air analyzers; multi-point validation of NO, SO₂, CO, CO₂, O₃.
Case Study →Calibration of GC, µGC, RGA/NGA, elemental, LPG analyzers and spectrometers.
Case Study →Custom mixtures for method development; linearity, LOD/LOQ and hysteresis testing.
Case Study →Secondary standards and VOC/aroma analysis; inert version for aggressive gases.
Case Study →Most asked questions about multi-line GasMix™ calibration, automation and metrology.
Bring traceable, automated gas calibration to your bench — powered by GasMix™.